HMS Omnia
Electromedical device with radiofrequency, fractional RF, Plasmaskin (FELC), electroporation and electrostimulation
- Technologies
- 5 in 1
- Radiofrequency
- 200 W · 500/1000 kHz
- Fractional RF
- 10-needle applicator
- FELC
- 35 kHz · 1000 Vpp
- Electroporation
- 120 Vpp · max 3 kHz
- Display
- 10.1" touch
Intended use
What it is for and who uses it
HMS Omnia is a non-invasive active therapeutic electromedical device employing the following technologies: Radiofrequency for skin resurfacing (xanthelasma, blepharoplasty), photoageing, skin laxity, acne, enlarged facial pores; Electrotherapy to stimulate the musculature and prevent atrophy from inactivity, and also to improve venous and lymphatic return resulting from the action of the "muscle pump"; Electroporation for the transdermal inoculation of therapeutic active ingredients.
Qualified operators
The intended use of the appliance is that of a "medical device", used exclusively by personnel qualified in accordance with the law for applications in the fields of physiotherapy, rehabilitation, pain therapy and aesthetic medicine. The prescription of the therapeutic protocols provided for with the device is a medical responsibility; paramedical personnel, qualified in accordance with the law, may operate only in the ways provided for by current legislation.
Treatments and areas
- Skin resurfacing (xanthelasma, blepharoplasty)
- Photoageing
- Skin laxity
- Acne
- Enlarged facial pores
- Muscle stimulation and prevention of atrophy from inactivity
- Venous and lymphatic return
- Transdermal inoculation of therapeutic active ingredients
Contraindications
- Radiofrequency: contraindicated for wearers of active implants such as pacemakers, insulin pumps, pericardial stimulators, hearing aids or others; for women who are pregnant and/or breastfeeding; for wearers of metal prostheses and osteosynthesis devices (including dental prostheses) close to the area to be treated; in cases of epilepsy; in subjects with ongoing inflammatory processes, skin lesions, dermatological conditions, progressive diseases or neoplasms (in particular in cases of metastasis); do not treat subjects with sensitive skin, or if necessary limit to very low output powers; apply only to intact skin; in subjects who have previously undergone lipofilling or non-resorbable filler treatments in the same area; subjects suffering from autoimmune diseases, coagulopathies or phlebopathies.
- Radiofrequency, in the presence of: growing cartilage (children or adolescents); hepatic dysfunction (hepatitis, cirrhosis, etc.); metabolic dysfunction (hypertriglyceridaemia, hypercholesterolaemia or diabetes); renal dysfunction or insufficiency (nephritis, nephropathies); osteoporosis, haemorrhage, menstruation; close to the cardiac region; close to "sensitive" organs (genital organs, ovaries, testicles, etc.); close to the major lymphatic areas (armpits, popliteal fossa, etc.); close to the thyroid or endocrine glands; localised or diffuse sensory paralysis; severe heart disease; circulatory disorders or hypertension (including hypotension, hypertension, varicose veins, thrombophlebitis, capillary fragility or telangiectasia); in the presence of tattoos or piercings in the areas to be treated.
- Electroporation/Electrostimulation: contraindicated for wearers of active implants such as pacemakers, insulin pumps, pericardial stimulators, hearing aids or others; for women who are pregnant and/or breastfeeding; for wearers of metal prostheses and osteosynthesis devices (including dental prostheses) close to the area to be treated; for subjects with ongoing inflammatory processes, skin lesions, neoplasms; do not treat subjects with sensitive skin, or if necessary limit to very low output powers; during menstruation (unless medically prescribed); apply only to intact skin; in subjects with multiple sclerosis (owing to spastic paralysis and sensory disorders); in subjects with Parkinson's disease (owing to rigidity from increased muscle tone and tremor); in the presence of febrile illness; in cases of epilepsy; in cases of thrombophlebitis; in cases of heart disease.
- Particular caution is required when treating the following: cuts, wounds, varicose veins, lips and mucous membranes in general. Avoid applying the electrodes/applicators: on the carotid sinuses and the anterior surface of the neck (to avoid spasms of the larynx and pharynx) so as not to stimulate the vagovagal reflex; the breast area, limited to the nipples and areola; the cardiac area (avoid placing the heart between the electrodes); the eye area (unless otherwise medically prescribed); around the head.
- Use of the equipment is contraindicated (unless otherwise medically prescribed) in the following cases: ongoing infectious processes; abrasions, wounds, localised skin conditions; persons hypersensitive or insensitive to temperature (for the use of radiofrequency). Facial treatments may interfere with hearing aids, which must be removed before application. In the case of treatments with botox injections and silicone products, do not carry out the treatment.
List taken from the instructions for use. Read the warnings and instructions carefully before use.
Technology
HMS Omnia is a non-invasive active therapeutic electromedical device that brings together radiofrequency, fractional radiofrequency, Plasmaskin with FELC technology, electroporation and electrostimulation in a single appliance. The manual describes it as the answer to the operator’s need to have several technologies available with which to modulate the intervention individually, since the therapeutic protocol must be personalised according to the condition and the specific characteristics of the treated subject.
It is available in two versions, HMS Omnia.M with metal case and HMS Omnia.P with plastic case, both managed by a 10.1-inch touch display. For each technology the treatment parameters can be set manually or preset programmes can be selected; delivery is controlled from the display and the double footswitch.
Radiofrequency
The therapeutic action is based on the variation of the electric field, which induces a current at the various tissue levels. The endogenous heat generated by the Joule effect within the substrates of interest is directly proportional to the impedance encountered: this makes it possible to be selective on the target at the various depth levels, leaving the first skin layer at an acceptable temperature. According to the manual, in aesthetic medicine the RF stimulus induces fibroblasts to produce new collagen, elastin and hyaluronic acid, while in physiotherapy it increases blood circulation, raises oxygen tension in the treated area, generates vasodilation, reduces muscle contractures and facilitates the reabsorption of oedema.
The RF section delivers up to 200 W @ 50 ohm with a software-selectable frequency of 500 kHz or 1000 kHz, capacitive or resistive emission, monopolar or bipolar characteristic, with dedicated applicators for large and small areas. In RF-MC System mode the radiofrequency is combined with electroporation, with separate adjustment of the two intensities.
Fractional radiofrequency
Fractional emission is defined as that which produces multiple partial injuries on the skin, generating micro-holes that induce the physiological self-repair process: between the micro-columns of dermo-epidermal denaturation, micro-areas of undamaged tissue remain that act as a biological reserve, facilitating the repair processes with activation of cellular metabolism and tissue remodelling. The dedicated MF 10-4 applicator has 10 needles; delivery is in single shot or burst mode, with pulse, pause, number of pulses, time and intensity adjustable, and is enabled at each press of the footswitch.
Plasmaskin – FELC
The Plasmaskin applicator uses FELC (Conveyed Electron Flow) technology which, employing very low powers, generates a thermal increase only in poorly conductive tissues while respecting the surrounding tissues. The generator works at 35 kHz with a voltage of 1000 Vpp @ 43 kOhm. The software offers programmes for eyelid, xanthelasma, acne, wrinkles, lentigo, scars, fibromas, warts, anti-age and a manual mode; delivery of the electric arc can be continuous, fractional (1–10 Hz) or single shot (500, 1000, 1500 or 2000 ms) and is enabled by holding the footswitch pressed.
Electroporation
Applying a particular electrical pulse to a biological surface generates aqueous channels in the cell membrane, known as electropores. The phenomenon induces a significant transient increase in tissue permeability, which promotes the transcutaneous absorption of water-soluble active ingredients. The active ingredient in aqueous solution is loaded with a syringe into the face/body applicator; depth of action (superficial, medium, deep), body area, intensity and time are set from the display. In manual mode the duration of the pulses and pauses and the frequency of the sinusoid can also be adjusted. Maximum voltage 120 Vpp @ 1 kOhm, pulse frequency up to 3 kHz, complex software-selectable waveform.
Electrostimulation
The physical principle of pulsed electrostimulation is based on low- or medium-frequency excitomotor currents applied to the electrodes, which stimulate the contraction and relaxation of the muscle concerned; the pump effect obtained from the muscle movement promotes lymphatic drainage of the treated part. In the intended use, electrotherapy is indicated to stimulate the musculature, prevent atrophy from inactivity and improve venous and lymphatic return. It uses the CREP applicator shared with the radiofrequency and the same generation section as the electroporation.
Handpieces and standard equipment
What comes in the box
Consumables: Radiofrequency gel, Active ingredients in aqueous solution for electroporation (syringe)
Technical specifications
Technical specifications
| Power supply | 100–240 V AC, 50–60 Hz |
|---|---|
| Max power consumption | 350 VA |
| Electrical safety class | II BF |
| IP rating | IP20 |
| External protection | Protection fuses 2 × 3.15 A |
| Versions | HMS Omnia.M (metal case) · HMS Omnia.P (plastic case) |
| Max RF output power | 200 W @ 50 ohm |
|---|---|
| RF emission frequency | 500 kHz, 1000 kHz software-selectable |
| Emission type | Capacitive / Resistive |
| Emission characteristic | Monopolar / Bipolar / Fractional |
| Fractional RF | Single shot or burst; pulse, pause and number of pulses adjustable |
| Working frequency | 35 kHz |
|---|---|
| Working voltage | 1000 Vpp @ 43 kOhm |
| Delivery modes | Continuous · Fractional (1–10 Hz) · Single shot (500/1000/1500/2000 ms) |
| Max voltage | 120 Vpp @ 1 kOhm |
|---|---|
| Pulse frequency | Max 3 kHz software-selectable |
| Waveform | Complex, software-selectable |
| Depth of action | Superficial / Medium / Deep |
| Display | 10.1" 16/9 colour, resistive touch (Omnia.M) or capacitive touch (Omnia.P) |
|---|---|
| Programmes | Manual parameters or preset programmes for each technology |
| Omnia.M dimensions (H × W × D) | 13 × 39 × 36 cm |
|---|---|
| Omnia.M weight | 8 kg |
| Omnia.P dimensions (H × W × D) | 17 × 41 × 32 cm |
| Omnia.P weight | 4.8 kg |
| Output parameter tolerance | 20 % |
| Operating temperature | 0 °C ÷ +40 °C |
|---|---|
| Operating humidity | 30 % ÷ 75 % non-condensing |
| Operating pressure | 700 ÷ 1060 hPa |
| Storage and transport | −10 °C ÷ +70 °C · max humidity 95 % · 500 ÷ 1060 hPa |
| Expected service life | 10 years (device and accessories) |
Output parameter tolerance: 20% (data from the instructions for use).
Compliance and certifications
Medical device · CE marking with Notified Body
- Notified Body
- 1370
- Manufacturer
- CTM Tech S.r.l.s., Terni (Italia)
- EUDAMED SRN
- IT-MF-000032025
- Quality system
- ISO 13485 · AQSCert
- IFU
- Rev. 08 · 2025-10-23
Documentation
Training and service
Training included at delivery, direct service from our Terni workshop, replacement unit in case of extended downtime, CEI EN 62353 electrical checks.
Also available for rental or leasing → options
Healthcare professionals area
HMS Omnia – information for healthcare professionals
Content reserved for healthcare professionals under the Italian Ministry of Health guidelines of 2 April 2025.
Enter as a healthcare professionalFrequently asked questions
Who may use HMS Omnia?
What is the difference between Omnia.M and Omnia.P?
How often must maintenance be carried out?
Related devices
HMS Carbo
Information reserved for healthcare professionals
Healthcare professionals area →HMS Omnia Wave
Information reserved for healthcare professionals
Healthcare professionals area →HMS Oxy Evo
Information reserved for healthcare professionals
Healthcare professionals area →Want to see it working in your treatment room?
On-site or online demo, quote and rental simulation within 48 hours.