Request a demo ☎
HBS – High Beauty System

HIFU

Focused ultrasound technology for Aesthetic Medicine

Five cartridges from 1.5 to 13 mm and transdermal delivery in an 8 kg console with a 10-inch touchscreen.

  • Face
  • Body
  • Skin laxity
  • Wrinkles
  • Firming
  • Hydration
  • Drainage

Draft: content being completed

HBS HIFU, front view
Drag to rotate

HBS HIFU is a technological device intended for the field of Aesthetic Medicine, which uses high-intensity focused ultrasound to concentrate energy at selected tissue depths.

The technology makes it possible to develop protocols dedicated to improving the appearance of the skin, skin firmness and counteracting the visible signs of ageing.

Thanks to the range of cartridges available, the system allows different application depths to be selected, adapting the treatment to the characteristics of the area concerned and to the aesthetic goals.

The platform also integrates a transdermal delivery function, which completes the device’s operating capabilities.

HBS HIFU is intended exclusively for use by authorised professionals, in compliance with the intended use declared by the manufacturer and with current regulations.

Five cartridges

Choose the cartridge, choose the depth.

Tap a cartridge: the focal point moves to its working depth.

Cartridge

Schematic illustration: depths to scale, tissues not shown.

4 MHz cartridge 051015 mm 4.5 mm
Focal point at 4.5 mm depth, 4 MHz cartridge.

In the box

  • Power cord
  • Transdermal delivery handpiece
  • Pair of conductive gloves (optional for delivery)
  • Conductive eco-leather facial mask (optional for delivery)

With CTM by your side

  • Training included

    At delivery we train you and your staff in the treatment room, and run refresher courses.

  • Service from Terni

    The workshop that built the device repairs it, with a replacement unit if downtime runs long.

  • Rental or leasing

    A monthly fee to start without tying up capital.

  • Made in Italy

    Designed, built and tested in our plant, unit by unit.

All the details

Technical specifications
General
Power supply 100–240 V AC, 50–60 Hz
Max power consumption 200 W
Electrical safety class II BF
IP rating IP40
External protection Fuses 2 × 3.15 A
Connectivity USB
Focused ultrasound (HIFU)
Cartridges (depth – frequency) 1.5 mm – 10 MHz · 3.0 mm – 7 MHz · 4.5 mm – 4 MHz · 8.0 mm – 4 MHz · 13.0 mm – 4 MHz
Energy from 0.1 to 2.0 J ± 20 % (0.1 J steps)
Mode Focused / Pulsed
Spot length Spot spacing adjustable from the console
Counters Spots per session and total per cartridge
Transdermal delivery
Max voltage 140 Vpp @ 1000 ohm
Carrier working frequency 1 ÷ 500 Hz
Waveform Complex
Emission frequency 1 ÷ 10 Hz
Depth levels Superficial · Medium · Deep
Interface, dimensions and environment
Display 10" 16/9 capacitive colour touchscreen
Size (H × W × D) 13 × 39 × 36 cm
Weight 8 kg
Operating temperature 0 °C ÷ +40 °C
Operating humidity 30 % ÷ 75 % non-condensing
Operating pressure 700 ÷ 1060 hPa
Storage and transport −10 °C ÷ +70 °C · max humidity 95 % · 500 ÷ 1060 hPa
Output parameter tolerance 20 %
Expected service life 10 years

Output parameter tolerance: 20% (data from the instructions for use).

Intended use and warnings

Intended use

HBS-HiFu is an electromechanical appliance for aesthetic use, employed for: High-intensity focused ultrasound (for lifting, wrinkle and firming treatments of skin laxity); Transdermal delivery (for faster absorption of the applied cosmetic product through the application of a low-intensity current; it allows specific substances to be introduced into the superficial, medium and deep layers, thereby promoting hydration, elasticity and drainage of every part of the face and body). TODO: validate translation against the English IFU.

Qualified operators

HBS-HiFu must be used exclusively under the continuous supervision of qualified personnel, such as a beautician. It is not a product with a medical intended use.

Contraindications

  • HIFU, contraindicated for use in subjects with: open wounds or lesions in the area to be treated; severe or cystic acne in the area to be treated; active implants (e.g. pacemakers or defibrillators) or metal implants in the treatment area; sensitive skin or subjects with telangiectasia, varicose veins and near moles; pregnant or breastfeeding women; subjects who have already undergone skin peeling with other systems or with mechanical vibration systems or with acids (glycolic, etc.) in the previous 30 days; subjects with active hearing implants and/or with hearing problems.
  • HIFU, treatment not recommended directly over: devices such as pacemakers, hearing devices and/or other electronic devices; mechanical implants; metal prostheses; dermal fillers; breast implants; keloids; reddened skin, open wounds, abrasions. During treatment avoid: thyroid gland, thyroid cartilage, trachea, major blood vessels, breast tissue, breast implants, proximity to bones, cartilage, reproductive system, cardiac region, neoplasms.
  • HIFU, device not evaluated for use in: subjects on an anticoagulant treatment plan; children; subjects with a bleeding disorder or haemostatic dysfunction, systemic or local skin disease that may impair wound healing, herpes simplex, autoimmune disease, thyroid disease, diabetes, epilepsy, Bell's palsy. Particular attention is required in the case of immune and thyroid disorders.
  • Transdermal delivery, contraindicated: for wearers of active implants such as pacemakers, insulin pumps, pericardial stimulators or others; for pregnant and/or breastfeeding women; for wearers of metal prostheses and osteosynthesis close to the area to be treated; for subjects with ongoing inflammatory processes, skin lesions or neoplasms; do not treat subjects with sensitive skin, or if necessary limit to very low output powers; during menstruation (unless medically prescribed); apply only to intact skin; in subjects with multiple sclerosis; in subjects with Parkinson's disease; subjects on anticoagulants; in the presence of febrile illness or fungal infections; in case of epilepsy; at the treatment site of a dermal filler; people taking finasteride or minoxidil; in case of diseases such as AIDS or syphilis; subjects with systemic lupus erythematosus, scar diathesis or skin cancer; in case of serious diseases of the heart, liver, kidneys or other internal organs and malignant tumours; subjects with class II or higher hypertension, heart disease, stroke or cerebral haemorrhage; in case of thrombophlebitis or severe diabetes.
  • General warnings: particular caution in the case of cuts, wounds, varicose veins, lips and mucous membranes in general. Avoid applying the electrodes/applicators over the carotid sinuses and the anterior surface of the neck, on the breast area limited to nipples and areola, in the eye area (unless otherwise medically prescribed) and around the head. Use contraindicated (unless otherwise medically prescribed) in the case of ongoing infectious processes, abrasions, wounds, localised skin diseases. Facial treatments may interfere with hearing aids, which must be removed before application.
  • Side effects: HIFU, moderate to severe pain during treatments; after treatments mild swelling, erythema, purpura, bruising, numbness, linear red streaks, which resolve in a short time without permanent complications. Transdermal delivery: rarely redness, skin erythema and/or prolonged oedema, resolving within a few days. Excessive power may cause burns, generally of a mild degree.

List taken from the instructions for use. Read the warnings and instructions carefully before use.

Compliance and documents
CE

Professional aesthetic appliance compliant with Italian Ministerial Decree 206/2015

DM 206/2015 technical sheet
Manufacturer
CTM Tech S.r.l.s., Terni (Italia)
Quality system
ISO 13485 · AQSCert
IFU
Rev. 00 · 2024-12-05

Frequently asked questions

How many cartridges are included and at what depths do they work?
The kit includes five cartridges of 1.5 mm (10 MHz), 3.0 mm (7 MHz), 4.5 mm, 8.0 mm and 13.0 mm (4 MHz). The console shows the model of the loaded cartridge, the working depth and the number of spots delivered in the session and over the life of the cartridge.
How is the energy adjusted?
The energy is set from 0.1 to 2.0 Joule in 0.1 J steps; the manual recommends starting with reduced power and choosing power and times according to the area treated. The spot length sets the distance between one shot and the next.
Is gel required?
Yes. A sufficient and even layer of ultrasound gel must be applied to the cartridge output and to the area to be treated, to ensure appropriate and safe transmission of the ultrasonic energy.
Who can use it?
The device must be used exclusively under the continuous supervision of qualified personnel, such as a beautician, in beauty centres. It is not a product with a medical intended use.

Want to try HIFU in your centre?