Request a demo ☎
HBS – High Beauty System

Element Skin

7 technologies. One ally for your professionalism.

Multifunction platform for professional treatment of the face, neck and décolleté

  • Face
  • Neck
  • Décolleté
  • Deep cleansing
  • Tone and firmness
  • Hydration

Draft: content being completed

HBS Element Skin, front view
Drag to rotate

Every skin has different needs. Why always offer the same treatment?

With HBS Element Skin you can combine seven technologies and create personalised facial programmes, from deep cleansing to treatments for radiance, hydration and the signs of skin ageing.

Discover the technologies

The periodic table of your treatment room.

Tap an element to discover it.

01 · Vacuum

Deep cleansing, beyond the surface.

Thanks to controlled suction, it helps remove impurities and excess sebum, offering targeted cleansing even in the most difficult areas. A valuable ally for preparing the skin for the treatments that follow.

In the box

Also included: Power cable.

With CTM by your side

  • Training included

    At delivery we train you and your staff in the treatment room, and run refresher courses.

  • Service from Terni

    The workshop that built the device repairs it, with a replacement unit if downtime runs long.

  • Rental or leasing

    A monthly fee to start without tying up capital.

  • Made in Italy

    Designed, built and tested in our plant, unit by unit.

All the details

Full description

HBS Element Skin was created to bring together, within a single platform, several technologies that can be used in professional protocols dedicated to the face, neck and décolleté. The central feature of the system is the possibility of building the treatment through different phases, combining skin surface preparation, radiofrequency, vacuum, transdermal delivery, Dermoscrub and photostimulation according to the selected protocol.

Radiofrequency uses electromagnetic energy to produce controlled heating of the tissues. Element Skin offers monopolar and bipolar modes, allowing the operator to modulate the work according to the area and the aesthetic goal. The system operates with capacitive radiofrequency at 1000 kHz, with power up to 50 W.

Vacuum introduces a mechanical component into the protocol. The controlled negative pressure mobilises the tissue and can be integrated into professional work aimed at stimulating superficial microcirculation and preparing the treated areas. The system reaches values down to -650 mmHg.

The Dermoscrub spatula works at 28 kHz with a power of 7 W. The ultrasonic action acts on the skin surface, helping to remove superficial corneal cells, impurities and sebum build-up. This phase can be used to prepare the skin for the subsequent steps of the treatment.

Element Skin also features a technology dedicated to the transdermal delivery of compatible cosmetics. The system uses a complex waveform with a carrier frequency between 1 and 500 Hz and an emission frequency between 1 and 10 Hz, with the aim of supporting the transdermal application of the cosmetic actives provided for by the protocol without the use of needles.

The platform also integrates photostimulation. In the configuration intended for the Italian market, the technical documentation indicates 808 nm and 850 nm infrared as the operating emissions; the red LED emission at 623 nm serves as a signalling/guide function.

The equipment includes the handpieces dedicated to the different functions: airbrush/infusion, radiofrequency and absorption handpiece, vacuum handpiece, Dermoscrub spatula and photostimulation handpiece. The 10-inch 16:9 capacitive touch display interface manages the different functions and their parameters.

Technical specifications
General characteristics
Power supply 100–240 V AC, 50–60 Hz
Max power consumption 500 W
Electrical safety class II BF
IP protection rating IP40
External protection Fuses 2 × 3.15 A
Connectivity USB · Wi-Fi
Optional Trolley
Radiofrequency
Max RF output power 50 W capacitive @ 50 ohm
RF emission frequency 1000 kHz
Type of emission Capacitive
Emission characteristic Monopolar / Bipolar
Vacuum
Type of emission Continuous
Max vacuum pressure −650 mmHg
Transdermal delivery
Max voltage 80 Vpp @ 1000 ohm
Carrier working frequency 1 ÷ 500 Hz
Waveform Complex
Emission frequency 1 ÷ 10 Hz
Photobiostimulation
Laser diodes 808 nm · 10 mW/cm² · continuous/pulsed · divergence 8°–36° · Class 1 (EN 60825:2015)
Infrared LED 850 nm · 10 mW/cm² · continuous/pulsed · 45°
Red guide LED 623 nm · 50 lm · light indicator only (Italian market)
Classification Exempt Group (EN 60601-2-57:2011)
Dermoscrub
Max output voltage 15 V
Working frequency 28 kHz
Max output power 7 W
Airbrush
Function Diffusion over the skin of air mixed with cosmetic products
Interface, dimensions and environment
Display 10" 16/9 capacitive colour touchscreen
Dimensions (H × W × D) 45 × 40 × 35 cm
Weight 17 kg
Operating temperature 0 °C ÷ +40 °C
Operating humidity 30 % ÷ 75 % non-condensing
Expected service life 10 years

Output parameter tolerance: 20% (data from the instructions for use).

Intended use and warnings

Intended use

HBS - ELEMENT SKIN is an electromechanical appliance for aesthetic use, employed for: radiofrequency (the monopolar/bipolar handpiece stimulates the fibroblasts to produce collagen and elastin naturally); vacuum (allows deep yet gentle cleansing and purification of the pores; removes impurities, cleanses, exfoliates and thoroughly purifies thanks to the replaceable tips); transdermal delivery (promotes the absorption of functional active ingredients and ensures deep hydration for all skin types); photostimulation (allows targeted work on areas with more pronounced blemishes); Dermoscrub (the ultrasonic spatula allows superficial exfoliation of the outer stratum corneum).

Qualified operators

It must be used exclusively under the continuous supervision of qualified personnel, such as a beautician. It is not a product with a medical intended use.

Contraindications

  • Radiofrequency: wearers of active implants (pacemakers, insulin pumps, pericardial stimulators or others); pregnancy and breastfeeding; metal prostheses and osteosynthesis devices close to the area to be treated; ongoing inflammatory processes, skin lesions, dermatological conditions, progressive diseases or neoplasms; sensitive skin (limit to very low power levels); apply only to intact skin; lipofilling and non-resorbable fillers in the same area; autoimmune diseases, coagulopathies or phlebopathies.
  • Radiofrequency, in the presence of: growing cartilage; hepatic, metabolic or renal dysfunction; osteoporosis, haemorrhage, menstruation; proximity to the cardiac region, sensitive organs, lymphatic areas, the thyroid or endocrine glands; sensory paralysis; severe heart disease; circulatory disorders or hypertension.
  • Vacuum: capillary fragility; telangiectasia.
  • Transdermal delivery: wearers of active implants; pregnancy and breastfeeding; nearby metal prostheses; inflammatory processes, skin lesions, neoplasms; sensitive skin; menstruation (unless medically prescribed); multiple sclerosis; Parkinson's disease; febrile illness; epilepsy; thrombophlebitis. Apply only to intact skin.
  • Photostimulation: damaged skin, ongoing infectious processes, any skin condition.
  • Dermoscrub: sensitive skin; telangiectasia, varicose veins and proximity to moles; pregnancy; wearers of cardiac stimulators; proximity to bones, cartilage, the reproductive system, the cardiac region, neoplasms, metal prostheses; skin peeling with other systems or acids in the last thirty days; reddened skin, open wounds, abrasions; active hearing implants or hearing disorders.

List taken from the instructions for use. Read the warnings and instructions carefully before use.

Compliance and documents
CE

Professional aesthetic appliance compliant with Italian Ministerial Decree 206/2015

DM 206/2015 technical sheet
21A
Manufacturer
CTM Tech S.r.l.s., Terni (Italia)
Quality system
ISO 13485 · AQSCert
IFU
Rev. 00 · 2024-08-30

Frequently asked questions

How long does a session last?
The treatment parameters that can be set from the console provide for a duration of between 20 and 60 minutes.
Is training required to use it?
Yes. The device must be used under the continuous supervision of qualified personnel (a beautician). CTM Tech includes training in its use with delivery and organises refresher courses.
Can it be mounted on a trolley?
Yes, the trolley is available as an optional extra.

More treatment possibilities. More value for your professionalism.

One device to broaden your treatment menu, combine different methods and offer clients increasingly personalised aesthetic programmes.

On-site or online demo, quote and rental simulation within 48 hours.